# 100mm Height Cable Tray

URL: https://www.chinneelectric.com/products-types/cable-tray-system/100mm-height-cable-tray/
Brand: Chinne Electric

## Summary
Chinne Electric Cable Tray. Available in hot-dip galvanized, fire-retardant powder coated, and standard powder coated finishes. Perforated design for heavy or medium-duty use.. Product Brief.

## Key facts
- Standards: IEC 61537
- Corrosion protection & aesthetics
- Fire-resistant, insulated & circuit-safe
- Heavy-duty corrosion protection, weather resistance

## Content
```html
Technical Specifications
Chinne Electric Cable Trays are manufactured in accordance with IEC 61537, covering design, material, and performance requirements for cable tray systems used in electrical installations. The perforated design facilitates ventilation and heat dissipation while maintaining structural integrity under specified load conditions.

    Material base: Mild steel sheet, cold-rolled, conforming to ISO 3574 CR4 grade or equivalent
    Width range: 50 mm to 600 mm (standard); custom widths available up to 900 mm
    Side rail height: 25 mm, 40 mm, 50 mm, 60 mm, 80 mm, 100 mm — depending on duty class
    Sheet thickness: 1.2 mm to 3.0 mm, selected per duty rating and span
    Perforation pattern: Slotted or round-hole; typical open area ratio ≥ 25% for ventilation
    Load classification (IEC 61537): Medium-duty (Type 2) and heavy-duty (Type 4) as standard; tested at 1.7× safe working load
    Span capability: 1.5 m to 3.0 m, deflection ≤ 1/100 of span under safe working load per IEC 61537
    Surface finishes:
        
            Hot-dip galvanized (HDG) — Fe/Zn12 per ISO 1461, minimum coating thickness 55 µm on steel ≥ 3 mm
            Fire-retardant powder coating — epoxy-based, flame propagation index ≤ 10 per IEC 60332-3 (bunched cable test equivalent)
            Standard powder coating — polyester, 60–80 µm DFT, RAL 7035 (light grey) default; other RAL colours on request
        
    
    Operating temperature range: -40 °C to +120 °C (HDG); -20 °C to +80 °C (powder-coated)
    Corrosion resistance: HDG suitable for C4 (high) corrosivity environments per ISO 12944-2; powder-coated suitable for C3 (medium)
    Joint type: Quick-connect splice plates with M6/M8 bolted fasteners, supplied with each straight length
    Standard length: 3 m per straight section (other lengths on request)


Application
Chinne Electric Cable Trays are designed for the structured routing and mechanical protection of power, control, instrumentation, and communication cables. Typical installations include:

    Industrial facilities: Factories, processing plants, and substations — supporting multi-circuit cable runs above machinery and in cable basements
    Commercial buildings: Office towers, hospitals, and retail complexes — distribution risers and horizontal runs above suspended ceilings
    Data centres: Segregation of power and data cable pathways under raised floors or overhead; perforated design assists thermal management
    Infrastructure projects: Tunnels, rail networks, airports, and water treatment plants — environments requiring corrosion-resistant finishes and reliable long-span performance

Hot-dip galvanized trays are specified for outdoor and high-humidity locations. Fire-retardant powder-coated trays are specified where circuit integrity under fire conditions is a design requirement. Standard powder-coated trays serve general-purpose indoor environments where aesthetics and moderate corrosion protection are sufficient.

Standards Compliance
Chinne Electric Cable Tray systems are designed, tested, and marked to the following international standard:

    IEC 61537:2023 — Cable tray systems and cable ladder systems for electrical installations. This standard governs definitions, construction, mechanical strength testing, protective conductor continuity, and marking requirements. Declaration of Performance (DoP) documentation is available on request.

Supplementary references applied during manufacturing and finishing:

    ISO 1461:2022 — Hot-dip galvanized coatings on fabricated iron and steel articles
    ISO 12944-2:2017 — Corrosion classification of environments (C2–C4)
    IEC 60332-1-2 — Flame propagation testing for single cables (referenced for coating ignition characteristics)


Frequently Asked Questions

What is the difference between medium-duty and heavy-duty cable tray under IEC 61537?
Under IEC 61537, medium-duty (Type 2) trays are rated for a safe working load that results in a maximum deflection of 1/100 of the span at the declared load. Heavy-duty (Type 4) trays meet the same deflection criterion at approximately 1.5× to 2× the load of a Type 2 tray of equivalent width and span. Selection depends on cable fill weight, support spacing, and whether concentrated loads are expected. Chinne Electric marks each product with its duty classification and maximum span per the standard.

Which surface finish should I specify for a chemical processing environment?
Hot-dip galvanized (HDG) to ISO 1461 is the primary recommendation for chemical processing areas, as it provides a robust zinc-iron alloy layer with a minimum 55 µm coating on steel substrates ≥ 3 mm. This finish is rated for C4 (high) corrosivity environments per ISO 12944-2, which covers most chemical plant conditions where occasional chemical splash or acidic vapours are present. For environments with concentrated acids or alkalis, contact Chinne Electric for alternative material grades or supplementary coatings. Fire-retardant powder coating is not intended as a primary corrosion barrier in aggressive chemical exposure.

Does the perforated design affect the current-carrying capacity of the cables installed in the tray?
Perforated trays promote air circulation around installed cables, which assists heat dissipation and can reduce derating factors compared to solid-bottom enclosures. In accordance with IEC 60364-5-52, cable grouping and installation method are the primary determinants of ampacity derating. The open area of Chinne Electric perforated trays (typically ≥ 25%) permits free air movement, and the tray itself does not impose additional derating beyond what the installation method code accounts for. For precise derating calculations, refer to the cable manufacturer's data and the applicable wiring rules of the installation jurisdiction.
```