Strut Channel 41x21mm
Chinne Electric Strut Channel 41×21 mm is a cold-formed, shallow C-channel framing system for mounting cable trays, conduits, pipes, ductwork, and equipment brackets. At half the depth of standard 41×21 mm strut, it is ideal for low-clearance ceiling runs, wall-mounted supports, and restricted-depth M&E installations
General information
Product Features
- Shallow half-strut profile: 41 mm wide × 21 mm deep—approximately half the depth of standard 41×41 mm strut. Suited to light-to-medium-duty loads where reduced installation height is required.
- Modular, weld-free framing: Continuous slotted channel with inturned edges allows channel nuts and brackets to be positioned anywhere along the length—no welding or site drilling for most connections.
- Wide system compatibility: Works with standard 41 mm strut accessories including spring nuts, channel nuts, angle brackets, beam clamps, threaded-rod hangers, and pipe/clamp fittings.
- Flexible installation: Suitable for wall, ceiling, and steel-structure mounting; layouts can be adjusted, extended, or reconfigured during installation or future upgrades.
- Multiple duty ratings: Available in light-duty (typically 1.5 mm) and heavy-duty (typically 2.5 mm) wall thicknesses to match project load requirements.
Dimensions & Specifications
Strut Channel 41×21 mm is a shallow-profile channel support member within the 41 mm strut family. It shares the same 41 mm mounting width as standard 41×41 mm strut, enabling full accessory interchangeability while offering a lower profile for space-critical applications.
Typical profile dimensions (indicative):
| Parameter | Value |
| Nominal width | 41 mm |
| Nominal height | 21 mm |
| Profile type | Shallow / half-strut C-channel |
| Thickness | 1.1mm to 3mm |
| Configuration | Slotted (perforated) or plain |
| Standard lengths | 3000 mm / 6000 mm |
| Custom lengths | Available on request |
Technical Specifications
- Product type: Slotted strut channel (channel support system)
- Profile: 41 × 21 mm shallow C-channel with inturned lip edges
- Manufacturing: Cold-formed from low-carbon strip steel
- Standard length: 3000 mm / 6000 mm (custom cut lengths available)
- Material options: Mild steel, stainless steel (SS304 / SS316L), aluminum
- Wall thickness: 1.1 mm to 3.0 mm available
- Slot pattern: Continuous slotted holes along one face (slotted variants)
- Surface finish: Pre-galvanized (PG), hot-dip galvanized (HDG), powder coated
- Accessory compatibility: Standard 41 mm strut nuts, brackets, and fixings
- Customization: Custom lengths, materials, finishes, and slot configurations available upon request
Surface Treatment Options
Different finishes are available for various environments.
| Aspect | Powder Coated | Pre-Galvanized (PG) | Hot Dip Galvanized (HDG) |
|---|---|---|---|
| Primary Objective | Corrosion protection & aesthetics | Cost-effective corrosion protection for indoor use | Heavy-duty corrosion protection, weather resistance |
| Surface Material / Treatment | Standard polyester, epoxy, or hybrid powder (organic polymers) | Zinc-coated steel sheet (pre-galvanized coil) | Zinc-iron alloy layer (pure zinc by hot-dip process) |
| Process | Electrostatic spray deposition + heat curing | Continuous galvanizing before forming | Immersion in molten zinc bath (~445 °C) forming metallurgical bond(pre-fabrication) |
| Coating Thickness | 60–120 µm | Typically 10–30 μm | Typically ≥65 µm (can be increased for aggressive environments) |
| Fire Performance | Combustible, produces smoke, no cable protection | Non-combustible (steel base) | Non-combustible (steel base), but no thermal insulation; zinc may vaporize under intense fire, cables still damaged |
| Corrosion Protection | Moderate (indoor, dry environments) | Moderate (indoor, dry environments) | Excellent (suitable for outdoor, marine, salt spray, chemical plants) |
| Surface Finish | Smooth, uniform gloss, wide colour range | Smooth, metallic, uniform | Dull silver-grey, may have zinc spangles or runs |
| Governing Standards | IEC 61537 | IEC 61537, EN 10346 | IEC 61537, ISO 1461 / ASTM A123 |
| Typical Applications | General indoor, offices, commercial spaces without special fire or severe corrosion | Indoor installations, commercial buildings | Outdoor cable trenches, coastal facilities, wastewater treatment, chemical plants, high humidity / high temperature areas |
| Relative Cost | Low | Low | Medium-high |
Applicable standards:
- BS 6946 (channel support systems)
- GB/T 23639-2017, JB/T 10216-2013 (cable support system reference)
- Compatible with IEC 61537 cable tray/ladder systems when used as the support structure
Technical Description
Strut channel is a modular metal framing system consisting of a cold-formed C-channel section with inturned lip edges and a continuous row of slotted holes. Brackets, channel nuts, and accessories lock into the inturned lips, creating secure, adjustable connections at any point along the channel without welding.
The 41×21 mm profile—often referred to as half-strut or shallow strut—is the lower-depth member of the 41 mm strut family. It provides the same 41 mm accessory interface as 41×41 mm standard strut but with reduced section depth, making it the preferred choice when:
- Ceiling void depth is limited
- Wall-mounted supports must sit close to the surface
- Light-duty cable containment, conduit, or pipe support is required
- A compact trapeze or hanger assembly is needed
In cable management applications, strut channel acts as the structural support framework from which cable trays, cable ladders, mesh trays, and conduit systems are suspended or wall-mounted—typically using threaded rod, trapeze brackets, or direct channel fixings. Strut systems are classified under channel support standards (BS 6946), while the cable trays and ladders they carry are governed by cable management standards such as IEC 61537.
Chinne Electric 41×21 mm strut channels are supplied in slotted and plain configurations, with material and finish options selected to match indoor, outdoor, and corrosive-environment project requirements.
Applications
- Cable support: Suspended and wall-mounted supports for cable tray, cable ladder, mesh tray, and cable containment systems
- Conduit & trunking: GI/EMT conduit runs, trunking, and cable containment mounting frames
- Pipe & duct support: Light-to-medium-duty pipe clamps, HVAC duct hangers, and mechanical service supports
- Electrical installations: Distribution board frames, panel mounting, busbar supports, and equipment brackets
- Low-clearance areas: Shallow ceiling voids, corridor soffits, and restricted-depth plant rooms
- Modular framing: Trapeze hangers, cantilever brackets, multi-tier support frames, and M&E coordination structures
- Industrial & infrastructure: Manufacturing plants, commercial buildings, data centers, transportation facilities, and renewable energy installations
Customization
- Custom cut lengths and bulk packaging
- Material: carbon steel, stainless steel (SS304 / SS316L), aluminum
- Finish: PG, HDG, standard powder coat, fire-retardant powder coat
- Slotted or plain profile
- Compatible brackets, nuts, threaded rod, and accessory packages
Strut Channel 41x21mm FAQ FAQs
Click a question to reveal the answer.
Chinne Electric Strut Channel 41x21mm is engineered for reliable performance in commercial and industrial installations, with documentation aligned to applicable international standards.
Refer to the product technical specifications for cited standards such as IEC, GB/T, or JB/T requirements relevant to cable systems and installation practice.
Typical applications include building electrical systems, industrial plants, infrastructure projects, and MEP installations requiring organized cable routing and long-term maintainability.
Selection should consider load, environment, corrosion protection, fire performance, and installation constraints. Contact Chinne Electric for project-specific guidance.
Chinne Electric supports customized dimensions, finishes, and project documentation for export and compliance requirements.