RUBBER CABLES
A trusted factory-direct supplier for all your rubber cable needs
Benefits of rubber cables
XTREM® is the best rubber cable choice. Our rubber cables offer several advantages: great flexibility, durability, and resistance to environmental challenges. They are known for their ability to bend easily, making them suitable for frequent movement or installation in confined spaces.
Typical applications of RUBBER CABLES
Rubber cables for industrial facilities
Rubber cables are ideal for industrial use, offering exceptional durability, flexibility, and resistance to oils, chemicals, and abrasion. They withstand harsh environments, ensure reliable power transmission, and meet international safety standards, making them perfect for heavy-duty machinery and demanding industrial applications.
Rubber cables for construction
Rubber cables are perfect for construction sites, providing superior durability, flexibility, and resistance to abrasion, moisture, and harsh weather. They ensure reliable power supply in tough conditions, meet safety standards, and withstand heavy use, making them ideal for temporary and permanent installations.
Rubber cables for oil and gas industry
Rubber cables excel in oil & gas applications, offering unmatched resistance to oils, chemicals, extreme temperatures, and abrasion. Their flexibility and durability ensure reliable power in harsh offshore and refinery environments, while meeting stringent safety standards for hazardous areas. Perfect for heavy-duty industrial operations.
Rubber cables for welding
Rubber cables are perfect for welding applications, providing superior flexibility for easy maneuverability and exceptional resistance to heat, sparks, and abrasion. Their durable construction ensures reliable power transmission in demanding conditions, while oil-resistant properties make them ideal for rugged industrial welding environments.
Rubber cables for mobile equipment and heavy machinery
Rubber cables deliver unmatched durability and flexibility for mobile machinery, withstanding constant movement, vibrations, and harsh conditions. Their superior resistance to oils, chemicals, and abrasion ensures reliable power transmission, making them ideal for construction, mining, and industrial heavy-duty applications.
Rubber cables for submersible pumps and drinking water
Rubber cables are specially designed for submersible pumps and offer superior waterproof performance, flexibility, and resistance to moisture, and corrosion. Their durable construction ensures safe, reliable operation in drinking water applications while meeting strict hygiene and international safety standards.
Rubber cables for aquaculture, fish farms, shrimp farms, and "living" water
Rubber cables excel in aquatic environments, offering superior waterproofing, flexibility, and resistance to algae, saltwater, and UV exposure. Their durable, non-toxic construction ensures safe, reliable power for pumps and aeration systems while meeting strict standards for water quality and marine life safety.
Rubber cables are ideal for industrial use, offering exceptional durability, flexibility, and resistance to oils, chemicals, and abrasion. They withstand harsh environments, ensure reliable power transmission, and meet international safety standards, making them perfect for heavy-duty machinery and demanding industrial applications.
Rubber cables are perfect for construction sites, providing superior durability, flexibility, and resistance to abrasion, moisture, and harsh weather. They ensure reliable power supply in tough conditions, meet safety standards, and withstand heavy use, making them ideal for temporary and permanent installations.
Rubber cables excel in oil & gas applications, offering unmatched resistance to oils, chemicals, extreme temperatures, and abrasion. Their flexibility and durability ensure reliable power in harsh offshore and refinery environments, while meeting stringent safety standards for hazardous areas. Perfect for heavy-duty industrial operations.
Rubber cables are perfect for welding applications, providing superior flexibility for easy maneuverability and exceptional resistance to heat, sparks, and abrasion. Their durable construction ensures reliable power transmission in demanding conditions, while oil-resistant properties make them ideal for rugged industrial welding environments.
Rubber cables deliver unmatched durability and flexibility for mobile machinery, withstanding constant movement, vibrations, and harsh conditions. Their superior resistance to oils, chemicals, and abrasion ensures reliable power transmission, making them ideal for construction, mining, and industrial heavy-duty applications.
Rubber cables are specially designed for submersible pumps and offer superior waterproof performance, flexibility, and resistance to moisture, and corrosion. Their durable construction ensures safe, reliable operation in drinking water applications while meeting strict hygiene and international safety standards.
Rubber cables excel in aquatic environments, offering superior waterproofing, flexibility, and resistance to algae, saltwater, and UV exposure. Their durable, non-toxic construction ensures safe, reliable power for pumps and aeration systems while meeting strict standards for water quality and marine life safety.
A complete solution from chinne
-
High quality Cable&cable support system manufacturer
Cable&cable support system manufacturer Chinne is one of Chinese leading cable&cable support system manufacturers which excels in providing best-in-class service.
-
Large
cable&cable support system stockLarge cable&cable support system stock Our large cable&cable support system stock is always ready to be shipped around the globe. -
Quality and
CertificatesQuality/Certificates In our state-of-the-art laboratories we subject our cable&cable support system to stringent product testing and quality controls. -
Best-in-class-service
Best-in-class-service A friendly and eficcient sales team and our excellent logistics will satisfy your cable requirements.
RUBBER CABLES
Back-to-Back Strut Channel 41x82mm
Strut Channel 41x41mm
PARALLEL AUDIO CABLE
Extra Heavy-Duty Cable Ladder
Inward Flanged Side Rail Cable Ladder System
China Standard Cable Ladder Tray
Perforated Cable Ladder
Strut Channel 41x21mm
Cable Trunking
Wire Mesh Cable Tray
Cable Tray
VV-F H05VV-F
RZ1MZ1-K
RZ1 AL
N2XH flex
Why choose our RUBBER CABLES
-
Resists crushing & impact damage
-
Reinforced Mechanical Protection
-
Built for Versatility and Durability in Fixed Armoured Applications
-
Quality You Can Trust – From an Industry Leader
-
Dedicated Technical Support Whenever You Need It
-
Excellence in Service, Mastery in Logistics.
RUBBER CABLES FAQs
Click a question to reveal the answer.
In the international market, rubber cables generally follow the European Harmonized <HAR> system or application-based codes. The Chinese system utilizes the GB (Guobiao) standard, which uses Pinyin initials to denote cable structure and material.
-
Chinese System (GB/T 5013): Common models include YC (Heavy-duty), YZ (Medium-duty), and YQ (Light-duty). The prefix "Y" stands for Yajiao (Rubber). YH is specifically for welding cables.
-
International System: Focuses on harmonized codes such as H07RN-F (Heavy-duty, oil-resistant), H05RR-F (Light-duty), and H01N2-D (Welding cable).
-
Materials: Chinese "Rubber" usually refers to natural or styrene-butadiene rubber, while international "RN" (Chloroprene/Neoprene) and "BN" (EPR) provide higher chemical and thermal resistance.
H07RN-F is a heavy-duty, flexible chloroprene-sheathed cable. Its reputation in the international market stems from its versatility:
-
Resilience: High resistance to mechanical stress and abrasion.
-
Environmental Protection: Excellent resistance to oils, chemicals, UV radiation, and extreme weather.
-
Application: Widely used in construction sites, mobile machinery, and drainage pumps where durability is non-negotiable.
These materials serve different roles in rubber cable construction:
-
EPR (Insulation): Known for superior dielectric strength and high-temperature stability (up to 90°C). It is often used as the primary insulation for the cores.
-
Chloroprene/Neoprene (Sheath): Used for the outer jacket. It provides the "toughness"—protecting the cable against tearing, oil ingress, and flame spread.
For mobile applications, the bending radius is critical. International standards suggest a minimum radius of 6x to 8x the Outer Diameter (OD). If the radius is too tight, the internal copper strands can suffer from fatigue and eventually fracture, leading to "hot spots" or complete circuit failure.
When installing rubber cables in Perforated Cable Trays, ensure the cables are not stacked too deep. Rubber cables generate more heat than PVC under load; stacking inhibits airflow. Using Stainless Steel Trays is recommended for corrosive industrial zones to match the longevity of the rubber jacket.
-
Wire Mesh Cable Trays: Ideal for lightweight rubber control cables and complex routing. They allow for easy entry/exit points through the mesh.
-
Cable Ladders: The preferred choice for heavy power-feed rubber cables (e.g., $3\times 95\text{mm}^2$). Ladders provide maximum ventilation and allow for secure fastening with Cable Cleats to withstand mechanical forces during a short-circuit.